Description
New Ocean SR2 delivers best-in-class SNR for configurable spectrometers.
Each Ocean SR2 also includes OceanDirect, a powerful, cross-platform Software Developers Kit.
- Optimized performance with high speed acquisition and great SNR
- Automated manufacturing techniques for repeatability
- Versatility for complex applications
- Available in 5, 10, 25, 50, 100 or 200 µm wide slits (please contact us directly for more information about slit widths other than 25 µm)
Optimized for Performance and Versatility
Ocean SR2’s combination of speed (integration times to 10 µs) and SNR (380:1) provides application versatility without the typical trade-offs. Ocean SR2 spectrometers are well suited for applications including laser characterization, plasma monitoring, and absorbance measurements that benefit from the instrument’s high SNR performance.
Each Ocean SR2 spectrometer comes with OceanDirect, a powerful, cross-platform Software Developers Kit (SDK) with an Application Programming Interface (API). OceanDirect provides users the capability to optimize spectrometer performance and access critical data for analysis.
Ocean SR2 spectrometers are compact, lightweight and optimized for best performance. Ocean SR2 is compatible with Ocean Insight light sources, accessories and software, allowing users to customize setups for different applications and sampling requirements.
Available SKUs*:
Model |
Wavelength Range |
Optical Resolution |
SR-2UV240-25 |
200nm - 530nm |
0.66 |
SR-2UVV240-25 |
185nm - 920nm |
1.33 |
SR-2UVV300-25 |
185nm - 920nm |
1.33 |
SR-2UVV400-25 |
185nm - 920nm |
1.33 |
SR-2VIS400-25 |
380nm - 1μm |
1.34 |
SR-2VIS750-25 |
570nm - 850nm |
0.56 |
SR-2VN500-25 |
350nm - 1μm |
1.34 |
SR-2XR250-25 |
185nm - 1.1μm |
1.71 |
SR-2N1000-25 |
650nm - 1.1μm |
1.30 |
*please contact us directly if you need a slit width different than 25 µm
General Specifications (recur across all SKUs):
Spectroscopy |
|
Wavelength Range |
185nm - 1.1μm |
Optical Resolution |
0.43, 0.56, 0.66, 1.30, 1.33, 1.34, 1.71 |
Integration Time |
1μs - 1.5s |
Corrected Linearity |
>99.8%(10-90% saturation) (10 µs - 1.5 s) |
Dark Noise |
20 Counts |
Dynamic Range |
3400:1 |
Input Fiber Connector |
SMA 905 |
Signal to Noise Ratio |
380:1 |
Stray Light |
2.3 AU |
Thermal Stability |
0.05 pixels/°C |
Detector |
|
Pixels |
2098 |
Entrance Slit |
25µm |
Electronics |
|
A/D Resolution |
16 bit |
Connectors |
USB Type-C 16-pin Samtec TFM |
Inputs/Outputs |
4 GPIO - 2 Output Strobes - Power Input - Trigger Input |
Trigger Modes |
Rising Edge - Level |
Power Consumption |
400mA max |
Communications |
|
Wired |
USB 2.0 |
Environmental |
|
Compliance |
CE FCC Part 15 Class A |
Humidity |
0-85% non-condensing |
Material |
Aluminum |
Operating Temperature |
0°C to 55°C |
Storage Temperature |
-30° to 70° C |
Physical |
|
Dimensions |
88.9mm x 63.5mm x 31.3mm (w/o ports |
Weight |
275g |